LICHROSPHER 100 RP 18 MANUAL AND TEST



Lichrospher 100 Rp 18 Manual And Test

Optimisation of thawing conditions for solutions of cefuroxime in. From open column to HPLC liquid chromatography and general liquid samplings, the Super Fraction Collector, model SF-3120 has a wide range of uses.The SF-3120 is a fraction collector with increased reliability, employs an X-Y movement mechanism based on long years of technological accumulation, a new vertical movement apparatus and a large display screen for easier use than ever., An overview of Resteks full offering of HPLC and UHPLC columns, specialty columns, and large molecule columns listing silica specifications, applications, chromatography properties, similar phases, and USP codes..

LC Columns Physical Characteristics Chart / HPLC & UHPLC

Column Protection Guide Version 0113. Search results for 13 14 110 at Sigma-Aldrich. Compare Products: Select up to 4 products. *Please select more than one item to compare, A simple, specific, accurate, and stability-indicating reversed-phase high-performance liquid chromatographic method was developed for the simultaneous determination of montelukast and fexofenadine hydrochloride, using a Lichrospher ® 100, RP-18e column and a mobile phase composed of methanol:0.1% o-phosphoric acid (90:10 v/v), pH 6.8.The retention times of montelukast and ….

Comparison Guide to C18 Reversed Phase HPLC Columns Introduction There are so many different C18 columns to choose from, that finding the right column for a particular separation Search results for hplc columns at Sigma-Aldrich. Compare Products: Select up to 4 products. *Please select more than one item to compare

separation is achieved using a RP-18 column, then it is possible to lower the amount of organic modifier so that the transferred analyte fraction is enriched at the top of the analytical column. 0 50 100 150 200 250 300 350 400 Phenytoin Na Carbamazepine Phenobarbital Theophylline LiChrospher® RP-18 ADS LiChrospher® RP-8 ADS LiChrospher® RP کد مرک 116487 الی 140931 . فروش ،پذیرش سفارش و واردات کلیه محصولات مرک آلمان با نام و کدهای زیر توسط شرکت کیمیانوآورآزما برای مشتریان محترم انجام می پذیرد :

An LC column capable of separating the analyte of interest from any interferences. A 12.5-cm × 4-mm i.d. LiChrospher 100 RP-18 column (Hewlett-Packard Company, part no. 79925OD-564) was used in this evaluation. An electronic integrator or some other suitable means of measuring peak areas or heights. A Waters Millennium Networking Computer Comparison Guide to C18 Reversed Phase HPLC Columns Introduction There are so many different C18 columns to choose from, that finding the right column for a particular separation

A simple, specific, accurate, and stability-indicating reversed-phase high-performance liquid chromatographic method was developed for the simultaneous determination of montelukast and fexofenadine hydrochloride, using a Lichrospher ® 100, RP-18e column and a mobile phase composed of methanol:0.1% o-phosphoric acid (90:10 v/v), pH 6.8.The retention times of montelukast and … Manufacturer of HPLC, Prep HPLC, Ion Chrom, SPE Spares - Thermo Hypersil Gold 5um, Column End Plugs For HPLC Columns, SS Tubings For HPLC and Welch HPLC Column Welchrom offered by Spectrum Marketing, Mumbai, Maharashtra.

Phenomenex is a global manufacturer of UHPLC, HPLC Columns, GC Columns, sample preparation products and chromatography accessories and consumables. Column Protection Guide Version 0113 Includes: • Mobile Phase Limitations • Column Storage Tips • Column Protection Devices. CoLuMn ProTeCTion guiDe TABLe oF ConTenTS INTRODUCTION TO COLUMN CARE AND USAGE 1-4 Selecting the Right Tubing and Fittings Column Installation PART I - SILICA-BASED & TWIN™ TECHNOLOGY COLUMNS 4-7 Running Parameters Column Equilibration …

Based on the results of our previous study we chose to test mechanisation by using a blender in the preparation process. Aim of our study was to ensure sufficient mixing capacity of the tested device in real life conditions and consequently to improve the uniformity of content in our capsules. Our objectives were to: Increase uniformity of content Meet pharmacopoeial criteria Establish reproducibility Material … Carotene and provitamin A content of vegetables sold in Viçosa, MG, Brazil, during spring and winter a high-pressure pump, manual injector with a 50-µL size loop, Lichrospher 100 column RP-18 (Merck; 5 µm, 250 mm long x 4 mm internal diameter), and UV-visible spec-trophotometer detector (model SPD 10 AV, Shimadzu) was used. Extraction of carotenoids Carotenoids were extracted according to the method …

Determination of imipenem and rifampicin in mouse plasma by

lichrospher 100 rp 18 manual and test

Determination of betulinic acid oleanolic acid and ursolic acid. All analysis were performed at ambient temperature (21°C) on a 250 × 4.6 mm LiChrospher ® 100 RP-18 column (Merck, Darmstadt, Germany) with 5 μm particles, protected with a guard column (4 x 4 mm) with the same packing material. The mobile phase consisted of acetonitrile:50 mM potassium dihydrogen phosphate pH 3.5 (40:60, v/v) and was, Comparison Guide to C18 Reversed Phase HPLC Columns Introduction There are so many different C18 columns to choose from, that finding the right column for a particular separation.

Fraction Collector for HPLC and Liquid Sampling BISCHOFF. To prevent the problem, an end-capped reversed-phase C 8 column, LiChrospher 100 RP-8 (e), was used. The retention decreased with increasing concentration of acetonitrile in the mobile phase, and addition of 2-4% (v/v) of acetic acid in the mobile phase was effective in the prevention of tailing peaks., Phenomenex is a global manufacturer of UHPLC, HPLC Columns, GC Columns, sample preparation products and chromatography accessories and consumables..

Phenomenex UHPLC HPLC SPE GC Leader in Analytical

lichrospher 100 rp 18 manual and test

Automated Extraction of 11-nor-A 9- Tetrahydrocannabinol. Search results for hplc columns at Sigma-Aldrich. Compare Products: Select up to 4 products. *Please select more than one item to compare https://en.wikipedia.org/wiki/Yamaha_MT-01 Stainless steel drain tap on 12,18, 26 & 38L models, bridge plate included Accessories For Stirred Baths Software For Programming TX150/TXf200, GR150/GP200 Includes Usb & RS232 Cable.

lichrospher 100 rp 18 manual and test

  • Find HPLC Columns and UHPLC columns (C18 C8 Phenyl and
  • LC Columns Physical Characteristics Chart / HPLC & UHPLC
  • (PDF) Effect of mulching materials on potato production in

  • All analysis were performed at ambient temperature (21°C) on a 250 × 4.6 mm LiChrospher ® 100 RP-18 column (Merck, Darmstadt, Germany) with 5 μm particles, protected with a guard column (4 x 4 mm) with the same packing material. The mobile phase consisted of acetonitrile:50 mM potassium dihydrogen phosphate pH 3.5 (40:60, v/v) and was 27-11-2011 · The HPLC system consisted of a pump (LC6A, Shimadzu, Tokyo, Japan) connected to an autosampler with a 100 μl loop (SIL-6B, Shimadzu) and controller (SCL-6B, Shimadzu) A guard column (LiChrospher 100-5 RP-18, Macherey-Nagel, Düren, Germany) was placed between the sample injection and the analytical column (LiChrospher 100 RP 18, 250 × 4 mm, 5

    Effect of mulching materials on potato production in different soil-climatic conditions. LiChrospher 100 RP-18 (5 µm) with . precolumn (Merck, Germany) LiChroCART (4-4 mm), LiChrospher 100 RP manual injector valve, Model 7725i fitted with a 20 l sam-ple loop. Separations were carried out using a LiChrospher® 100 RP-18 (125mm×4mm i.d., 5 m) cartridge column (Merck, Darmstadt, Germany) protected by a LiChrospher®

    Save valuable hood space by locating the instrument on a bench with the fume enclosure option. RP–UFLC-DAD analysis was performed on Shimadzu chromatographic system (Model no. LC-20AD) consisting of a quaternary pump, manual injector, degasser (DGU-20A5), and dual λ UV absorbance diode array detector SPD-M20A. Chromatographic separation was achieved on a Hibar 250–4.6 mm, 5 μ, Lichrospher 100, C18e column. An isocratic system

    Save valuable hood space by locating the instrument on a bench with the fume enclosure option. Stainless steel drain tap on 12,18, 26 & 38L models, bridge plate included Accessories For Stirred Baths Software For Programming TX150/TXf200, GR150/GP200 Includes Usb & RS232 Cable

    LiChrospher® 100 RP-8 and RP-8 endcapped HPLC columns are traditionally produced spherical silica gel carriers with C-8 or C-8 endcapped reversed-phase properties. Thanks to their great versatility, the columns are suitable for acidic, neutral and weakly basic compounds. The columns’ optimal selectivity and performance ensure reproducible LiChrospher® WP 300 RP-18 is a highly selective and reliable HPLC column for the separation of peptides and low molecular weight proteins. LiChrospher® WP 300 RP-18 enables the tailing-free separation of basic compounds and is ideally suited for the separation of tRNA. LiChrospher® PAH is a highly efficient and selective HPLC column

    All analysis were performed at ambient temperature (21°C) on a 250 × 4.6 mm LiChrospher ® 100 RP-18 column (Merck, Darmstadt, Germany) with 5 μm particles, protected with a guard column (4 x 4 mm) with the same packing material. The mobile phase consisted of acetonitrile:50 mM potassium dihydrogen phosphate pH 3.5 (40:60, v/v) and was PERMABOND ® P-100 PERMABOND ® SE-54 HKW OPTIMA ® 1 TG / 17 TG PERMABOND ® Silane PERMABOND ® CW 20 M-DEG Precolumns GC accessories Ferrules Capillary connectors Valco FS/FSR adapters Septa GC tools GC test mixtures USP list of MN GC phases GC Troubleshooting Flash/Adsorbents Flash chromatography Flash RS cartridges

    A simple, specific, accurate, and stability-indicating reversed-phase high-performance liquid chromatographic method was developed for the simultaneous determination of montelukast and fexofenadine hydrochloride, using a Lichrospher ® 100, RP-18e column and a mobile phase composed of methanol:0.1% o-phosphoric acid (90:10 v/v), pH 6.8.The retention times of montelukast and … a LiChrospher 100 RP-18 reversed phase column (250 4mm; 10mm) and the mobile phase of methanol:water, in gradient mode, were found as the most suita-ble. The derivatives were eluted in 10min with good reproducibility at a flow rate of 0.9mL=min, being 20mL the volume of sample injected. The detection was

    Determination of imipenem and rifampicin in mouse plasma by

    lichrospher 100 rp 18 manual and test

    LiChrosorbВ® RP-18 (5 Вµm) LiChroCARTВ® 250-4 151355. Step #3: Compare to Other Columns : To find the columns that are most similar to the one selected above, sort the column database below by F s so that the smallest F s values are listed first. To find the columns that are most different from the one selected above, sort the column database below by F s so that the largest F s values are listed first.. Select filters to narrow down the list of stationary phases., manual injector valve, Model 7725i fitted with a 20 l sam-ple loop. Separations were carried out using a LiChrospher® 100 RP-18 (125mm×4mm i.d., 5 m) cartridge column (Merck, Darmstadt, Germany) protected by a LiChrospher®.

    PP-002 The European Association of Hospital Pharmacists

    HPLC Column Configurator analytics-shop.com. manual injector valve, Model 7725i fitted with a 20 l sam-ple loop. Separations were carried out using a LiChrospher® 100 RP-18 (125mm×4mm i.d., 5 m) cartridge column (Merck, Darmstadt, Germany) protected by a LiChrospher®, LiChrosorb® RP-18 is a reliable irregular shaped silica gel carriers with reversed phase properties. It is well suited for the separation of neutral, acidic and weak basic compounds. This sorbent is packed into a LiChroCART® 250-4 HPLC cartridge. The connection to the HPLC system is being accomplished by use of the manu-CART® NT cartrige holder (1.51486)..

    27-11-2011 · The HPLC system consisted of a pump (LC6A, Shimadzu, Tokyo, Japan) connected to an autosampler with a 100 μl loop (SIL-6B, Shimadzu) and controller (SCL-6B, Shimadzu) A guard column (LiChrospher 100-5 RP-18, Macherey-Nagel, Düren, Germany) was placed between the sample injection and the analytical column (LiChrospher 100 RP 18, 250 × 4 mm, 5 Rheodyne offers manual high-pressure switching valves to simplify process operations and improve the speed, resolution and sensitivity of HPLC analysis. The switching valves are available in 316 stainless steel and PEEK, with either 1.6 mm (1/16 ") or 3.2 mm (1/8") ports. Column Selection The six-position valves are used for column selection

    The injector was a Rheodyne manual injection valve Model 7725, fitted with a 20-μL sample loop. Separations were carried out using a Lichrospher ® 100 RP-18 column (125 mm × 4.6 mm I.D., 5 μm) (Merck, Darmstadt, Germany) preceded by a guard column (10 mm × 4.6 mm I.D., 3 μm) of the Stainless steel drain tap on 12,18, 26 & 38L models, bridge plate included Accessories For Stirred Baths Software For Programming TX150/TXf200, GR150/GP200 Includes Usb & RS232 Cable

    RP–UFLC-DAD analysis was performed on Shimadzu chromatographic system (Model no. LC-20AD) consisting of a quaternary pump, manual injector, degasser (DGU-20A5), and dual λ UV absorbance diode array detector SPD-M20A. Chromatographic separation was achieved on a Hibar 250–4.6 mm, 5 μ, Lichrospher 100, C18e column. An isocratic system 15-08-2013 · The extract eluted from the SPE cartridges was purified, and ergosterol was quantified on a high-performance liquid chromatograph (HPLC) consisting of two Jasco PU-980 (Tokyo, Japan) pumps, a Jasco AS-950 autosampler, a LichroSpher 100 RP-18 column (0.46 by 25 cm; Merck Inc., Darmstadt, Germany), and a Jasco MD 2010 Plus multiwavelength

    کد مرک 116487 الی 140931 . فروش ،پذیرش سفارش و واردات کلیه محصولات مرک آلمان با نام و کدهای زیر توسط شرکت کیمیانوآورآزما برای مشتریان محترم انجام می پذیرد : Carotene and provitamin A content of vegetables sold in Viçosa, MG, Brazil, during spring and winter a high-pressure pump, manual injector with a 50-µL size loop, Lichrospher 100 column RP-18 (Merck; 5 µm, 250 mm long x 4 mm internal diameter), and UV-visible spec-trophotometer detector (model SPD 10 AV, Shimadzu) was used. Extraction of carotenoids Carotenoids were extracted according to the method …

    27-11-2011 · The HPLC system consisted of a pump (LC6A, Shimadzu, Tokyo, Japan) connected to an autosampler with a 100 μl loop (SIL-6B, Shimadzu) and controller (SCL-6B, Shimadzu) A guard column (LiChrospher 100-5 RP-18, Macherey-Nagel, Düren, Germany) was placed between the sample injection and the analytical column (LiChrospher 100 RP 18, 250 × 4 mm, 5 PERMABOND ® P-100 PERMABOND ® SE-54 HKW OPTIMA ® 1 TG / 17 TG PERMABOND ® Silane PERMABOND ® CW 20 M-DEG Precolumns GC accessories Ferrules Capillary connectors Valco FS/FSR adapters Septa GC tools GC test mixtures USP list of MN GC phases GC Troubleshooting Flash/Adsorbents Flash chromatography Flash RS cartridges

    LUNA® Luna Test Conditions: Column stability tested under highly acidic conditions. Continuous flush in 0.1% TFA (pH 1.5) in Water/Acetonitrile, 50:50. Test Conditions: Column stability tested under highly basic conditions. Continuous flush in 20mM Na 2 HPO 4 (pH 10.0) in Water/Acetonitrile, 50:50. If Luna does not provide at least an equivalent separation as compared to a competing column of the same … The injector was a Rheodyne manual injection valve Model 7725, fitted with a 20-μL sample loop. Separations were carried out using a Lichrospher ® 100 RP-18 column (125 mm × 4.6 mm I.D., 5 μm) (Merck, Darmstadt, Germany) preceded by a guard column (10 mm × 4.6 mm I.D., 3 μm) of the

    Column Protection Guide Version 0113 Includes: • Mobile Phase Limitations • Column Storage Tips • Column Protection Devices. CoLuMn ProTeCTion guiDe TABLe oF ConTenTS INTRODUCTION TO COLUMN CARE AND USAGE 1-4 Selecting the Right Tubing and Fittings Column Installation PART I - SILICA-BASED & TWIN™ TECHNOLOGY COLUMNS 4-7 Running Parameters Column Equilibration … Manufacturer of HPLC, Prep HPLC, Ion Chrom, SPE Spares - Thermo Hypersil Gold 5um, Column End Plugs For HPLC Columns, SS Tubings For HPLC and Welch HPLC Column Welchrom offered by Spectrum Marketing, Mumbai, Maharashtra.

    HPLC Column Configurator - Find and Compare HPLC Columns. With the help of our Liquid Chromatography Column Configurator, you can easily find the HPLC column you are looking for. Choose from around 80,000 HPLC columns from more than 30 quality manufacturers and brands, such as Agilent Technologies, Grace, Merck Millipore, Thermo Scientific, or Phenomenex is a global manufacturer of UHPLC, HPLC Columns, GC Columns, sample preparation products and chromatography accessories and consumables.

    EcoCART® 125-3 LiChrospher® 100 RP-18 endcapped (5 µm) HPLC glass cartridge 151431 LiChroCART® 250-4.6 HPLC cartridge, customized packing, please specify packing material manual injector valve, Model 7725i fitted with a 20 l sam-ple loop. Separations were carried out using a LiChrospher® 100 RP-18 (125mm×4mm i.d., 5 m) cartridge column (Merck, Darmstadt, Germany) protected by a LiChrospher®

    Optimisation of thawing conditions for solutions of cefuroxime in

    lichrospher 100 rp 18 manual and test

    Stability-indicating HPLC Method for Simultaneous Determination. 27-11-2011 · The HPLC system consisted of a pump (LC6A, Shimadzu, Tokyo, Japan) connected to an autosampler with a 100 μl loop (SIL-6B, Shimadzu) and controller (SCL-6B, Shimadzu) A guard column (LiChrospher 100-5 RP-18, Macherey-Nagel, Düren, Germany) was placed between the sample injection and the analytical column (LiChrospher 100 RP 18, 250 × 4 mm, 5, All analysis were performed at ambient temperature (21°C) on a 250 × 4.6 mm LiChrospher ® 100 RP-18 column (Merck, Darmstadt, Germany) with 5 μm particles, protected with a guard column (4 x 4 mm) with the same packing material. The mobile phase consisted of acetonitrile:50 mM potassium dihydrogen phosphate pH 3.5 (40:60, v/v) and was.

    Litter Supply as a Driver of Microbial Activity and Community

    lichrospher 100 rp 18 manual and test

    Stability-indicating HPLC Method for Simultaneous Determination. To prevent the problem, an end-capped reversed-phase C 8 column, LiChrospher 100 RP-8 (e), was used. The retention decreased with increasing concentration of acetonitrile in the mobile phase, and addition of 2-4% (v/v) of acetic acid in the mobile phase was effective in the prevention of tailing peaks. https://en.wikipedia.org/wiki/Fairchild_Republic_A-10_Thunderbolt_II LiChrosorb® RP-18 is a reliable irregular shaped silica gel carriers with reversed phase properties. It is well suited for the separation of neutral, acidic and weak basic compounds. This sorbent is packed into a LiChroCART® 250-4 HPLC cartridge. The connection to the HPLC system is being accomplished by use of the manu-CART® NT cartrige holder (1.51486)..

    lichrospher 100 rp 18 manual and test

  • HPLC Prep HPLC Ion Chrom SPE Spares Thermo Hypersil Gold
  • An alternative LC-UV procedure for the determination of
  • An alternative LC-UV procedure for the determination of

  • PERMABOND ® P-100 PERMABOND ® SE-54 HKW OPTIMA ® 1 TG / 17 TG PERMABOND ® Silane PERMABOND ® CW 20 M-DEG Precolumns GC accessories Ferrules Capillary connectors Valco FS/FSR adapters Septa GC tools GC test mixtures USP list of MN GC phases GC Troubleshooting Flash/Adsorbents Flash chromatography Flash RS cartridges Rheodyne offers manual high-pressure switching valves to simplify process operations and improve the speed, resolution and sensitivity of HPLC analysis. The switching valves are available in 316 stainless steel and PEEK, with either 1.6 mm (1/16 ") or 3.2 mm (1/8") ports. Column Selection The six-position valves are used for column selection

    PERMABOND ® P-100 PERMABOND ® SE-54 HKW OPTIMA ® 1 TG / 17 TG PERMABOND ® Silane PERMABOND ® CW 20 M-DEG Precolumns GC accessories Ferrules Capillary connectors Valco FS/FSR adapters Septa GC tools GC test mixtures USP list of MN GC phases GC Troubleshooting Flash/Adsorbents Flash chromatography Flash RS cartridges Learn more about Chromatography Columns. We enable science by offering product choice, services, process excellence and our people make it happen.

    manual injector valve, Model 7725i fitted with a 20 l sam-ple loop. Separations were carried out using a LiChrospher® 100 RP-18 (125mm×4mm i.d., 5 m) cartridge column (Merck, Darmstadt, Germany) protected by a LiChrospher® 27-11-2011 · The HPLC system consisted of a pump (LC6A, Shimadzu, Tokyo, Japan) connected to an autosampler with a 100 μl loop (SIL-6B, Shimadzu) and controller (SCL-6B, Shimadzu) A guard column (LiChrospher 100-5 RP-18, Macherey-Nagel, Düren, Germany) was placed between the sample injection and the analytical column (LiChrospher 100 RP 18, 250 × 4 mm, 5

    LiChrospher® WP 300 RP-18 is a highly selective and reliable HPLC column for the separation of peptides and low molecular weight proteins. LiChrospher® WP 300 RP-18 enables the tailing-free separation of basic compounds and is ideally suited for the separation of tRNA. LiChrospher® PAH is a highly efficient and selective HPLC column a LiChrospher 100 RP-18 reversed phase column (250 4mm; 10mm) and the mobile phase of methanol:water, in gradient mode, were found as the most suita-ble. The derivatives were eluted in 10min with good reproducibility at a flow rate of 0.9mL=min, being 20mL the volume of sample injected. The detection was

    Carotene and provitamin A content of vegetables sold in Viçosa, MG, Brazil, during spring and winter a high-pressure pump, manual injector with a 50-µL size loop, Lichrospher 100 column RP-18 (Merck; 5 µm, 250 mm long x 4 mm internal diameter), and UV-visible spec-trophotometer detector (model SPD 10 AV, Shimadzu) was used. Extraction of carotenoids Carotenoids were extracted according to the method … From open column to HPLC liquid chromatography and general liquid samplings, the Super Fraction Collector, model SF-3120 has a wide range of uses.The SF-3120 is a fraction collector with increased reliability, employs an X-Y movement mechanism based on long years of technological accumulation, a new vertical movement apparatus and a large display screen for easier use than ever.

    Save valuable hood space by locating the instrument on a bench with the fume enclosure option. separation is achieved using a RP-18 column, then it is possible to lower the amount of organic modifier so that the transferred analyte fraction is enriched at the top of the analytical column. 0 50 100 150 200 250 300 350 400 Phenytoin Na Carbamazepine Phenobarbital Theophylline LiChrospher® RP-18 ADS LiChrospher® RP-8 ADS LiChrospher® RP

    Manufacturer of HPLC, Prep HPLC, Ion Chrom, SPE Spares - Thermo Hypersil Gold 5um, Column End Plugs For HPLC Columns, SS Tubings For HPLC and Welch HPLC Column Welchrom offered by Spectrum Marketing, Mumbai, Maharashtra. Column care and use Column hardware HPLC and UHPLC columns from Merck Millipore come in a variety of different column hardware formats and materi-als for different applications. All columns have 10-32 UNF female end fittings that connect to 1/16” capillary tubing.

    To prevent the problem, an end-capped reversed-phase C 8 column, LiChrospher 100 RP-8 (e), was used. The retention decreased with increasing concentration of acetonitrile in the mobile phase, and addition of 2-4% (v/v) of acetic acid in the mobile phase was effective in the prevention of tailing peaks. An overview of Resteks full offering of HPLC and UHPLC columns, specialty columns, and large molecule columns listing silica specifications, applications, chromatography properties, similar phases, and USP codes.

    Phenomenex is a global manufacturer of UHPLC, HPLC Columns, GC Columns, sample preparation products and chromatography accessories and consumables. An LC column capable of separating the analyte of interest from any interferences. A 12.5-cm × 4-mm i.d. LiChrospher 100 RP-18 column (Hewlett-Packard Company, part no. 79925OD-564) was used in this evaluation. An electronic integrator or some other suitable means of measuring peak areas or heights. A Waters Millennium Networking Computer